Editing
Main Page
(section)
From pc5271AY2526wiki
Jump to navigation
Jump to search
Warning:
You are not logged in. Your IP address will be publicly visible if you make any edits. If you
log in
or
create an account
, your edits will be attributed to your username, along with other benefits.
Anti-spam check. Do
not
fill this in!
==Projects== ===[[Fluorescence Sensor for Carbon Quantum Dots: Synthesis, Characterization, and Quality Control]]=== Group menber: Zhang yiteng, Li Xiaoyue, Peng Jianxi This project aims to develop a low-cost, repeatable optical sensing system to quantify the quality of Carbon Quantum Dots (CQDs). We synthesize CQDs using a microwave-assisted method with citric acid and urea, and characterize their fluorescence properties using a custom-built setup comprising a UV LED excitation source and a fiber-optic spectrometer. By analyzing spectral metrics such as peak wavelength, intensity, and FWHM, we establish a robust quality control protocol for nanomaterial production. ===[[Inductive Sensors of Ultra-high Sensitivity Based on Nonlinear Exceptional Point]]=== Team members: Yuan Siyu; Zhu Ziyang; Wang Peikun; Li Xunyu We are building two coupled oscillating circuits: one that naturally loses energy (lossy) and one that gains energy (active) using a specific amplifier that saturates at high amplitudes. When tuning these two circuits to a nonlinear Exceptional Point (NEP), the system becomes extremely sensitive to small perturbations in inductance, following a steep cubic-root response curve, while remaining resistant to noise. '''CK:''' We likely have all the parts for this, but let us know the frequency so we can find the proper amplifier and circuit board. '''SY:''' Thanks for your confirmation. The operating frequency is around 70-80 kHz. '''CK:''' Have! ===[[EA Spectroscopy as a series of sensors: Investigating the Impact of Film-Processing Temperature on Mobility in Organic Diodes]]=== Team members: Li Jinhan; Liu Chenyang We will use EA spectroscopy, which will include optical sensors, electrical sensors, and lock-in amplifiers, among other components as a highly sensitive, non-destructive optical sensing platform to measure the internal electric field modulation response of organic diodes under operating conditions, and to quantitatively extract carrier mobility based on this measurement. By systematically controlling the thin film preparation temperature and comparing the EA response characteristics of different samples, the project aims to reveal the influence of film preparation temperature on device mobility and its potential physical origins. ===[[Optical Sensor of Magnetic Dynamics: A Balanced-Detection MOKE Magnetometer]]=== Team members: LI Junxiang; Patricia Breanne Tan Sy We will use a laser-based magneto-optical Kerr effect setup featuring a high-sensitivity differential photodiode array to measure the Kerr rotation angle induced by surface magnetism. This system serves as a versatile optical platform to investigate how external perturbations such as magnetic fields or radiation source alter the magnetic ordering of materials, allowing for the quantitative extraction of the magneto-optical coupling coefficients of various thin films. ===[[Precision Measurement of Material and Optical Properties Using Interferometry]]=== Team members: Yang SangUk; Zhang ShunYang; Xu Zifang We will be constructing an interferometer and use it as a tool for precision measurement. One primary objective is determination of the refractive index of various gases by analyzing the resulting shift interference fringes. ===[[Precision Thermocouple Based Temperature Measurement System]]=== Team members: Sree Ranjani Krishnan; Nisha Ganesh ; Burra Srikari We will design, build, and validate a precision thermocouple-based temperature measurement system using the Seebeck effect. The system will convert the extremely small thermoelectric voltage generated by a thermocouple into accurate, real-time temperature data. Since the output voltage is really small we will be using an instrumentation amplifier to amplify the output voltage and use an Arduino to digitalize the results. Materials needed: K-type thermocouple/Thermophile;Arduino
Summary:
Please note that all contributions to pc5271AY2526wiki are considered to be released under the Creative Commons Attribution (see
Pc5271AY2526wiki:Copyrights
for details). If you do not want your writing to be edited mercilessly and redistributed at will, then do not submit it here.
You are also promising us that you wrote this yourself, or copied it from a public domain or similar free resource.
Do not submit copyrighted work without permission!
Cancel
Editing help
(opens in new window)
Navigation menu
Page actions
Main Page
Discussion
Read
Edit
Edit source
History
Page actions
Main Page
Discussion
More
Tools
Personal tools
Not logged in
Talk
Contributions
Log in
Navigation
Main page
Recent changes
Random page
Help about MediaWiki
Search
Tools
What links here
Related changes
Special pages
Page information