Precision Measurement of Material and Optical Properties Using Interferometry
Team Members
Yang SangUk
Zhang ShunYang
Xu Zifang
List of Apparatus
Light source: 780nm laser diode (GH0781RA2C SHARP diode) with LT230-B collimation tube
Optics: optical isolator (Thorlabs IO-3D-780-VLP), beamsplitter, two 25.4mm broadband dielectric mirrors (BB1-E02-10)
Salt water of different concentrations in a transparent container (for determining the refractive index of solutions of different concentrations)
Analog powermeter
Oscilloscope (Rohde & Schwarz RTB2004, 100MHz bandwidth)
Idea
We will be constructing an interferometer as a tool for precision measurement. One primary objective is to determine the refractive index of the solutions of different salt concentrations by analyzing the resulting shift in interference fringes. Additionally, the thermal expansion of the metal sample will be measured by monitoring changes in the optical path length as the temperature of the sample varies. The project will highlight the relationship between wave optics and measurable physical parameters and illustrate the advantages of high-precision experimental technique.
Theory
An interferometer is a precision scientific instrument in which a light wave is split into multiple paths and later recombined. The resulting interference depends on the relative phase difference accumulated along the different paths. Because the phase is sensitive to path length and optical properties, interferometers are widely used for precision measurements. A common example is the Michelson interferometer, which illustrates the basic principles of optical interference.
The basic version of the Michelson interferometer consists of a 50:50 beam splitter (BS) and two mirrors placed in separate arms of the interferometer. Assume that the input beam is a linearly polarized monochromatic source of wavelength and field amplitude . The light is incident on the input port of the BS, where it is divided into two beams that propagate along the two arms toward the mirrors. Each beam is reflected by its respective mirror and recombined at BS, producing an interference pattern at the output port.
The output electric field can be described by summing the two contributions from the two arms. If the path lengths are and , the output field:
where and . Field maxima occur whenever
and minima when
where is an integer.
Changes in the optical path length of either arm caused by displacement of a mirror, or variation of refractive index in a medium will change the relative phase difference, leading to a shift of the interference fringes. he high sensitivity of the interference pattern to such changes forms the basis for precision measurements using a Michelson interferometer.
For example, a transparent container of length can be placed in one arm of the interferometer. The container is initially filled with air (refractive index approximately 1), and is then gradually filled with a solution of refractive index . The presence of the solution changes the optical path length in that arm. The additional optical path difference introduced by the solution is
where the factor of 2 arises because the light passes through the container twice (forward and backward).
The corresponding phase change is
As the concentration of the solution changes, the refractive index varies, leading to a continuous shift of the interference fringes. By counting the fringe shifts at the output port, the change in optical path length can be determined, allowing us to measure the dependence of the refractive index on the solution concentration.
Experiment setup & procedures
A basic Michelson interferometer will be constructed for the experiment.
Interferometer Alignment and Stability
Schematic of the Michelson interferometer. OI: optical isolator; M: mirror; BS: beam splitter; PM: powermeter
After constructing the interferometer, the beams reflected from both mirrors were carefully aligned so that they recombined at the beam splitter. The resulting interference signal was monitored using an analog power meter.
During the early stage of the interferometer construction, several sources of fluctuations that could affect the stability of the interference signal were identified:
Optical feedback into the laser diode: Reflected light entering the laser cavity can cause intensity fluctuations and frequency instability.
Counter: An optical isolator was added to suppress back reflections.
Mechanical vibrations: Vibrations from the environment (for example, people walking near the setup) could be observed as fluctuations in the signal on the oscilloscope.
Counter: Sorbothane vibration-isolation feet (Thorlabs AV4) were placed under the aluminum breadboard to provide basic vibration and acoustic isolation.
Air currents: Air movement around the optical paths can change the optical path length through refractive index variations.
Counter: The entire interferometer setup was enclosed inside a styrofoam box to reduce airflow and improve thermal stability.
Peak & Trough voltage is distinguished, while having intentionally created noises neglected.
Dataset "24MAR-05" has a peak voltage 1.70166 V and trough voltage 1.59912 V. The red section in the plot represents the neglected noises, which accounts for 8.8% of the dataset.
Dataset "24MAR-06" has a peak voltage 2.11182 V and trough voltage 2.01415 V.
2. Refractive index measurement Place the test solution in one arm of the interferometer. Gradually vary the solution concentration by adding either distilled water or a higher-concentration solution to the container, and observe the resulting changes in the interference pattern.
3. Thermal expansion measurement To investigate the thermal expansion of the mirror, slowly heat one of the mirrors using a heating resistor. The temperature will be monitored with a thermocouple. Record how the interference pattern changes as the temperature increases.
References
M. Fox, "Quantum Optics: An Introduction", (Oxford University Press, 2006) Chap. 2.
Archived
With Isolater
Oscilloscope Measurement without Sample (Low Pass Filter applied)
Oscilloscope Measurement with Intentional Noise created (Without Sample)
Peak -> Constructive Interference
Trough -> Destructive Interference
Bright and dark levels: use the slowly filtered signal to estimate a local bright level and a local dark level.
Quadrature target: V_target = (V_bright + V_dark) / 2.
Fringe half-swing: A = (V_bright - V_dark) / 2. It is the local voltage sensitivity scale. The larger A is, the more phase information is available per unit voltage change.
Small-signal phase estimate near quadrature: delta_phi is approximately delta_V / A in radians.