Introduction

Carbon dioxide (CO2) is a critical greenhouse gas whose concentration monitoring is essential for various applications, including environmental protection, industrial process control, and indoor air quality management. One effective method for detecting CO2 concentrations relies on the molecule's specific absorption characteristics in the infrared region.

CO2 exhibits a strong absorption peak at a wavelength of 4.26 μm, which corresponds to its fundamental vibrational mode. By exploiting this property, we can design an optical detection system that measures the intensity attenuation of infrared light at this wavelength as it passes through a gas chamber containing CO2. According to the Beer–Lambert law, the degree of light absorption is directly related to the concentration of the absorbing gas, enabling quantitative analysis:

A=log10(I0I)=εcL

In this project, we aim to develop such a detection apparatus. The system comprises an infrared light source centered at 4.26 μm, a gas chamber, and an infrared detector. By monitoring the reduction in light intensity after it traverses the gas chamber, the CO2 concentration can be inferred. This method offers non-invasive, real-time measurement capabilities and has the potential for high sensitivity and specificity.

Procedure

The experiment aimed to quantify the CO2 concentration by monitoring the voltage output from a photodetector, which corresponds to the transmitted infrared light intensity at the characteristic wavelength of 4.26 μm. A broadband infrared light source was used, and a narrow-band filter isolated the desired wavelength. The gas chamber used for the measurements had a fixed volume of 80 mL. The procedure was as follows:

  1. System Setup
  • A broadband infrared light source was used to emit light through the gas chamber (volume: 80 mL).
  • A narrow-band optical filter centered at 4.26 μm was placed before the photodetector to ensure only light at this wavelength reached the sensor.
  • A photodetector (light intensity sensor) was connected to a data acquisition system, which recorded the output voltage corresponding to the detected light intensity.
System Setup
  1. Initial Measurement
  • With ambient air (approximately 400 ppm CO2) in the gas chamber, the initial sensor output voltage V0 was measured and recorded as the baseline.
  1. CO2 Injection and Voltage Recording
  • Controlled increments of CO2 gas were introduced into the 80 mL gas chamber, gradually increasing the CO2 concentration.
  • After each increment, the output voltage V from the photodetector was measured and recorded.
  • The process was repeated for multiple concentration levels to establish the relationship between CO2 concentration and sensor voltage output.
  1. Data Recording and Analysis
  • The voltage outputs V0 (initial) and V (at each CO2 level) were systematically recorded.
  • A calibration curve was plotted with CO2 concentration on the x-axis and photodetector output voltage on the y-axis, representing the detection characteristic.

Results and Analysis

The following tables present the measured output voltages from the photodetector corresponding to different CO2 concentrations. Each voltage value represents an individual measurement, and an average is calculated from three groups.

Time (s) CO2 (%) Group 1 (mV) Group 2 (mV) Group 3 (mV)
0 0.042 241.9 238.0 237.6
1 32 233.1 215.9 223.3
2 48 176.0 166.6 173.6
3 58 165.6 160.8 156.6
4 65 149.7 155.4 156.7
5 70 139.0 143.0 139.3
6 73 129.0 132.2 129.1
7 76 132.7 129.4 133.7
8 79 121.2 115.7 125.6
9 81 120.5 115.5 121.6
10 82 116.0 114.2 114.6
11 83 110.7 113.1 113.0
12 84 107.7 107.6 108.2
13 85 104.7 102.3 102.4
14 86 99.0 101.4 100.8

Table: Raw voltage measurements across three groups

We use the averaged voltage response as a function of CO2 concentration:

V(c)=280.45e0.01057c

where:

  • V: output voltage (in mV)
  • c: CO2 concentration (in %)
CO2 Concentration vs. Photodetector Output Voltage

Analysis

Nonlinear Voltage Response to CO2 Concentration

The relationship between output voltage and CO2 concentration is not strictly linear. In the low concentration range (e.g., from 0.042% to around 30%), the voltage drops slowly, whereas at higher concentrations the decline becomes significantly steeper. This behavior can be attributed to the logarithmic nature of infrared absorption and the nonlinear response of the photodetector—where sensitivity increases as light intensity decreases.

System Imperfections and External Influences

Due to limitations in the experimental setup, complete gas sealing could not be achieved, potentially causing gas leakage or imperfect mixing. In addition, uncontrolled external infrared sources may have introduced optical noise into the system, affecting the sensor output. This optical interference is one of the main contributors to measurement uncertainty and reduces the system’s repeatability and precision.

Conclusion

In this project, we successfully developed a CO2 sensing system based on infrared absorption at the characteristic wavelength of 4.26 μm. By monitoring the voltage output of a photodetector and analyzing its response to varying CO2 concentrations, we demonstrated a clear and repeatable inverse correlation between gas concentration and detector output.

Although minor deviations were observed—primarily due to environmental noise, limited gas sealing, and optical interference—the overall results confirmed the system's sensitivity to CO2 levels. The fitted exponential model further validated the expected behavior derived from the Beer–Lambert law.

Despite inherent measurement uncertainties, the system reliably responded to changes in CO2 concentration, indicating the successful realization of a functional gas sensor prototype.